MIL-R-62197A(AT)
4.3 Inspection conditions. Unless otherwise specified herein, all inspections shall be performed under the following standard (room) ambient conditions:
a. Temperature: 77 + 18 F.
b. Relative humidity: Uncontrolled room ambient.
c. Atmospheric pressure: Site pressure.
4.4 First article inspection. First article inspection shall be performed on preproduction and initial production samples as specified herein. Approval of the first article sample by the Government shall not relieve the contractor of the obligation to supply relays that are fully representative of those inspected as a first article sample. Any changes or deviations of the production units from the first article sample shall be subject to the approval of the contracting officer.
4.4.1 Preproduction inspection. When specified (see 6.2), the preproduction sample shall consist of two relays. Preproduction inspection shall consist of inspection as specified in table I and the examination of 4.5.2.
4.4.2 Initial production inspection. Unless otherwise specified (see 6.2), the Government shall select two from the first ten relays produced under the production contract for initial production inspection. The initial production sample shall be inspected as specified in table I,
and examined as specified in 4.5.2.
4.4.3 First article inspection failure. Deficiencies found during, or as result of, the first article inspection shall be caused for rejection of the first article sample until evidence has been provided by the contractor that corrective action has been taken to eliminate the deficiency. Any deficiency found during, or as a result of, the first article inspection shall be evidence that all items already produced prior to completion of the first article test are similarly deficient unless contrary evidence satisfactory to the contracting officer is furnished by the contractor. Such deficiencies on all items shall be corrected by the contractor. The Government will not accept products until first article inspection is completed to the satisfaction of the Government.
4.5 QCI. QCI shall include the examination of 4.5.2 and the tests of 4.5.3. Noncompliance with any of the specified requirements in sections 3 and 5 shall be cause for rejection of the sample and the inspection lot.
4.5.1 Sampling plan. Unless otherwise specified (see 6.2), the sampling plan specified herein shall be used. See 6.4 for definitions of sampling inspection terms.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business